----------------------------------------------------------------------------- Process a response from the Z-Wave PC interface -----------------------------------------------------------------------------
| 6295 | // Process a response from the Z-Wave PC interface |
| 6296 | //----------------------------------------------------------------------------- |
| 6297 | bool Driver::HandleMemoryGetByteResponse |
| 6298 | ( |
| 6299 | uint8* _data |
| 6300 | ) |
| 6301 | { |
| 6302 | bool res = true; |
| 6303 | // the meaning of this command and its response is currently unclear |
| 6304 | // it seems to return three bytes of data, so print them out |
| 6305 | Log::Write( LogLevel_Info, GetNodeNumber( m_currentMsg ), "Received reply to FUNC_ID_ZW_MEMORY_GET_BYTE, returned data: 0x%02hx 0x%02hx 0x%02hx", _data[0], _data[1], _data[2] ); |
| 6306 | |
| 6307 | return res; |
| 6308 | } |
| 6309 | |
| 6310 | //----------------------------------------------------------------------------- |
| 6311 | // <Driver::HandleReadMemoryResponse> |