| 701 | } |
| 702 | |
| 703 | ModelObject AirLoopHVAC_Impl::clone(Model model) const { |
| 704 | auto airLoopClone = Loop_Impl::clone(model).cast<AirLoopHVAC>(); |
| 705 | |
| 706 | airLoopClone.setString(supplyInletPort(), ""); |
| 707 | airLoopClone.setString(supplyOutletPortA(), ""); |
| 708 | airLoopClone.setString(supplyOutletPortB(), ""); |
| 709 | airLoopClone.setString(demandInletPortA(), ""); |
| 710 | airLoopClone.setString(demandInletPortB(), ""); |
| 711 | airLoopClone.setString(demandOutletPort(), ""); |
| 712 | |
| 713 | // Sizing:System was already cloned because it is declared as a child |
| 714 | // And because it has the setParent method overriden, no need to do anything |
| 715 | |
| 716 | { |
| 717 | auto clone = availabilitySchedule().clone(model).cast<Schedule>(); |
| 718 | airLoopClone.setPointer(OS_AirLoopHVACFields::AvailabilitySchedule, clone.handle()); |
| 719 | } |
| 720 | |
| 721 | { |
| 722 | auto avmListClone = availabilityManagerAssignmentList().clone(model).cast<AvailabilityManagerAssignmentList>(); |
| 723 | avmListClone.setName(airLoopClone.name().get() + " AvailabilityManagerAssigmentList"); |
| 724 | airLoopClone.setPointer(OS_AirLoopHVACFields::AvailabilityManagerListName, avmListClone.handle()); |
| 725 | } |
| 726 | |
| 727 | airLoopClone.getImpl<detail::AirLoopHVAC_Impl>()->createTopology(); |
| 728 | |
| 729 | struct HVACPath |
| 730 | { |
| 731 | HVACPath(const HVACComponent& t_originalStart, const HVACComponent& t_originalEnd, const HVACComponent& t_clonedStartOrEndOfPath, |
| 732 | const Node& t_clonedAddNode, bool t_reverse) |
| 733 | : originalStart(t_originalStart), |
| 734 | originalEnd(t_originalEnd), |
| 735 | clonedStartOrEndOfPath(t_clonedStartOrEndOfPath), |
| 736 | clonedAddNode(t_clonedAddNode), |
| 737 | reverse(t_reverse){}; |
| 738 | |
| 739 | HVACComponent originalStart; |
| 740 | HVACComponent originalEnd; |
| 741 | HVACComponent clonedStartOrEndOfPath; // If reverse is false, it's the start, if reverse is true, it's the end |
| 742 | Node clonedAddNode; |
| 743 | bool reverse; |
| 744 | }; |
| 745 | |
| 746 | std::vector<HVACPath> pathsToHandle; |
| 747 | |
| 748 | if (isDualDuct()) { |
| 749 | // Add the Splitter to make it a dual duct |
| 750 | auto supplyInletNodeClone = airLoopClone.supplyInletNode(); |
| 751 | ConnectorSplitter supplySplitterClone(model); |
| 752 | supplySplitterClone.addToNode(supplyInletNodeClone); |
| 753 | airLoopClone.getImpl<detail::AirLoopHVAC_Impl>()->setSupplySplitter(supplySplitterClone); |
| 754 | |
| 755 | auto supplyOutletNodeClones = airLoopClone.supplyOutletNodes(); |
| 756 | |
| 757 | auto supplySplitter = this->supplySplitter().get(); |
| 758 | auto supplyInletNode = this->supplyInletNode(); |
| 759 | auto supplyOutletNodes = this->supplyOutletNodes(); |
| 760 |
no test coverage detected